When Old Technology Meets the Present Day
This is a cautionary tale about how many businesses maintain years and years of data storage. They’ve maintained servers and stored them on disks using RAID 5 technology. It’s a reliable system, but when you need to retrieve data, it can present a lot of costly complexities, as one of our clients recently discovered.
Our client was having trouble retrieving data and asked us to take a look. They gave us a half-dozen or so drives, and our immediate problem was that we couldn’t just pop them into a machine and take a look.
The problem was that our client had a server configured for RAID 5. In technical terms, RAID 5 is a configuration – redundant array of independent disks – that utilizes disk striping with parity. It enables you to distribute data across multiple drives with a parity check. This ensures data integrity even if one drive fails, and the configuration makes fast data retrieval possible.
However, it requires a minimum of three drives to function properly, and you need detailed record keeping to retrieve your data. That’s where the problem comes in. You need to take a Sharpie and identify each RAID 5 drive you have from the oldest to the newest. If you can’t view them in their proper sequence, you can’t retrieve your data.
If you have data on RAID 5 disks, you should consult an IT pro to see if you can dump your data to an external drive. However, it won’t be cheap. The cost can be $250 to $500 per disk to copy data to an external drive. The more disks you have, the harder it can be – unless you absolutely have them in the right sequence. And the process can be more difficult – if not impossible – if a disk is inadvertently fouled.
A better choice is RAID 1, commonly referred to as disk mirroring. Hard disks are kept in sync with one another so that if a disk were to fail, an exact copy remains, ensuring no loss.
In the event of a drive failure, recovery is easy since the duplicate drive can take over immediately. Read performance can be enhanced as data can be read from multiple disks simultaneously. The major drawback is that storage capacity is diminished, which means you’ll need more disks. In our opinion, that could outweigh the drawbacks of RAID 5, which requires more time and resources to rebuild data after a drive failure and can have slower write operations because of the need to update parity information.
We can help you determine which storage need is better for you or help you organize RAID 5 disks for more efficient data retrieval. Call us – 973-433-6676 – or email us to discuss what’s better for you.
Categories
Comments
Recent Posts
Recent Comments
- D. J. Hawkins on Health Wearables in Style at CES
- Allan Berger on Tech Preps for Trips
- Stan Schnitzer on We’re Not Neutral on Net Neutrality
- Allan Berger on Equifax and Protecting Your Identity
- Michael L. on Brave New Wireless World
Archives
- March 2025
- February 2025
- December 2024
- November 2024
- October 2024
- September 2024
- July 2024
- June 2024
- April 2024
- March 2024
- February 2024
- January 2024
- December 2023
- November 2023
- October 2023
- September 2023
- August 2023
- July 2023
- June 2023
- May 2023
- April 2023
- March 2023
- February 2023
- January 2023
- December 2022
- November 2022
- October 2022
- September 2022
- August 2022
- June 2022
- May 2022
- April 2022
- February 2022
- January 2022
- December 2021
- November 2021
- October 2021
- September 2021
- August 2021
- July 2021
- June 2021
- May 2021
- April 2021
- March 2021
- February 2021
- January 2021
- December 2020
- November 2020
- October 2020
- September 2020
- August 2020
- July 2020
- June 2020
- April 2020
- March 2020
- February 2020
- January 2020
- December 2019
- November 2019
- October 2019
- September 2019
- August 2019
- July 2019
- June 2019
- May 2019
- April 2019
- March 2019
- February 2019
- January 2019
- December 2018
- November 2018
- October 2018
- September 2018
- August 2018
- June 2018
- May 2018
- April 2018
- March 2018
- February 2018
- January 2018
- December 2017
- November 2017
- October 2017
- September 2017
- July 2017
- June 2017
- May 2017
- March 2017
- February 2017
- January 2017
- December 2016
- November 2016
- October 2016
- September 2016
- August 2016
- June 2016
- May 2016
- April 2016
- March 2016
- February 2016
- January 2016
- December 2015
- November 2015
- October 2015
- September 2015
- July 2015
- June 2015
- May 2015
- April 2015
- March 2015
- February 2015
- January 2015
- December 2014
- November 2014
- October 2014
- September 2014
- August 2014
- July 2014
- June 2014
- May 2014
- April 2014
- March 2014
- February 2014
- January 2014
- December 2013
- November 2013
- October 2013
- September 2013
- August 2013
- July 2013
- June 2013
- April 2013
- March 2013
- February 2013
- January 2013
- December 2012
- November 2012
- October 2012
- September 2012
No comment yet, add your voice below!